When will a Hunter X-Core water again after a rain delay?
On a Hunter X-Core, the programmable rain delay counts down at midnight on the controller's clock. When the count reaches zero, automatic watering becomes eligible at the next scheduled start. A one-day setting made late in the evening can therefore expire within hours. Check the next watering day and start time before recording a restart date for the maintenance team.
What to do
- Confirm which beds share the controller. The rain delay suspends all programmed watering on that unit. After heavy rain in an open courtyard, check the potting mix in any sheltered planters on the same controller before choosing a delay for the whole site.
- To set a temporary delay on this model, turn the dial to SYSTEM OFF and wait for OFF to appear. Use the plus button to select one to seven days. Return the dial to RUN and check the display shows OFF and the remaining number. Photograph the display and dial together for the handover.
- Write down the controller's date and time, the selected count and the next eligible programmed start. Count midnight crossings first, then consult the watering calendar. A station scheduled only on Tuesdays and Fridays can remain idle after the counter clears on a Wednesday.
What to avoid
- Treating a two-day delay as a 48-hour timer. If you set it just before midnight, the first decrement follows shortly afterwards.
- Leaving the dial at SYSTEM OFF when the estate expects an automatic restart. Hunter's timed procedure ends with the dial at RUN. Check that final position before locking the cabinet.
A practical check
Suppose the controller clock shows Monday at 6 pm and the courtyard normally waters every morning at 7 am. Set two days off. The count falls to one at the start of Tuesday and zero at the start of Wednesday. With the dial at RUN and no other watering restriction active, the next scheduled start is Wednesday at 7 am. Put that time in the log so the incoming gardener knows when to inspect the beds.