How much metered water reaches the estate lawn?
A sprinkler submeter records water passing through a pipe. Catch cups measure the depth landing on the turf. A maintenance team can compare the two during one run to investigate a high water reading before changing the controller schedule.
What to do
- Choose one zone and a dry, calm test period. Trace which outlets the meter serves. Record its units and take a photo immediately before and after the run. If another zone or washdown tap on the same meter was in use, repeat when you can isolate the sprinkler demand.
- Measure the turf footprint in square metres, excluding paths and planting beds. For an L-shaped lawn, split it into two non-overlapping rectangles and add their areas. Set identical catch cups in an evenly spaced grid over that footprint and calculate the mean depth in millimetres.
- Multiply the mean depth by the turf area to estimate litres landing on the grass. Subtract the starting meter reading from the ending reading. If the meter counts cubic metres, multiply the difference by 1,000 to get litres.
What to avoid
- Rounding the meter to whole cubic metres can hide a short watering run. Use the smallest marked increment and record it with the readings. If it is too coarse to resolve the difference, report that limitation.
- Calling the difference a leak. Check for spray landing outside the measured area, an unrepresentative cup layout or another outlet on the meter. Water landing on the turf can also run off afterwards.
A practical check
Suppose the lawn covers 120 square metres and the cups average 3 mm. About 360 litres reached the turf. A submeter rise from 48.120 to 48.600 cubic metres means 480 litres passed through the pipe. The estimated share caught on turf is 75%. Sketch where the remaining spray might have landed and check those edges during the next test.
FAO illustrated explanation of water depth, area and volume. For the sampling layout, see how to measure sprinkler coverage across a lawn.
LeaforaGet in touch